        Type 1001

        Type 1001

        產品詳細

        Type 1001 I/P & E/P Transducers
        • 0.1% accuracy typical
        • Closed loop pressure feedback control minimizes effects of vibration, temperature, supply pressure and mounting angle
        • Built-in volume booster provides flows up to 12 SCFM
        • Easy access zero and span adjustment
        • Damping pot prevents over shoot and “hunting”
        • Low air consumption
        • Mounts at any angle (NEMA 3R limited)
        • Compact and lightweight
        • Virtually no sensitivity to supply pressure changes
        • Removable orifice for easy maintenance
        Product Detail:
        The Type 1001 is a patented family of electro-pneumatic instruments that is used to reduce a supply pressure to a regulated output pressure which is directly proportional to a two-wire current or three-wire voltage input. This design incorporates closed loop sensing of the output pressure to achieve excellent accuracy and vibration stability. It also features a unique damping circuit which can be adjusted to prevent overshoot and actuator “hunting.” Model selection includes General Purpose (NEMA 1), Rainproof (NEMA 3R), and Watertight/Corrosion Resistant (NEMA 4X). NEMA 4X models are also explosion-proof, and all models are intrinsically safe.
        Part Numbers:
        Create Part Number:
        9
        6
        X
        XX
        X
        0
        XX
        6
          NEMA 1, General Purpose2 Enclosures
        7
          NEMA 3R, Rainproof2
        8
          NEMA 4X, Water-tight, Dust-tight, Corrosion Resistant, & Explosion Proof
        XX
          See/Input Output Matrix Below1 Calibration
        0
          None Agency Approvals
        1
          Factory Mutual & CSA Explosion Proof
        00
        None Options
        06
        Fluorocarbon Elastomeric Diaphragm
        notes to nomenclature:
        1. Transducer operating in the voltage mode (E/P), can be adjusted with the “span” potentiometer for any input between 0-10 VDC. The input range is limited to a minimum 4VDC difference between 100% and 0% Input voltage.
        2. Standard NEMA 1 enclosure is conversion coated only. Standard NEMA 3R and NEMA 4X enclosures are epoxy painted.

        T1001 Standard Input/Output Matrix
        psig
        0-5
        0-15
        0-30
        0-60
        0-100
        1-17
        3-15
        3-27
        6-30
        3-9
        9-15
        0-
        2
        0-
        120
        4-20mA
        19
        6
        20
        8
        9
        5
        2
        3
        4
        0
        1
        13
        7
        10-50 mA
        11
        16
        85
        98
        89
        15
        12
        87
        14
        10
        90
        91
        17
        0-5 VDC
        21
        26
        18
        28
        29
        25
        22
        35
        24
        30
        31
        92
        27
        1-5 VDC
        81
        36
        86
        38
        39
        97
        32
        33
        34
        50
        41
        93
        37
        1-9 VDC
        82
        46
        40
        48
        49
        45
        42
        43
        44
        60
        51
        94
        47
        1-10 VDC
        83
        56
        96
        58
        59
        55
        52
        53
        54
        88
        61
        95
        57
        0-10 VDC
        84
        66
        70
        68
        69
        65
        62
        63
        64
        80
        99
        23
        67
        Options:
        T1001 Accessories-Kits Part Number
        Panel Mounting Kit
        010135-000
        Valve Mounting Kit *** 010134-000
        2" Pipe Mounting Kit (Valve Mounting Kit is required) 010143-000
        DIN Rail Adapter 010115-000
        Cover for Locking Device Kit (for NEMA 4X enclosure only) 010136-000
        Type 1 Orifice with Buna-N O-rings* 010137-000
        Type 1 Orifice with Viton O-rings* 010137-002
        Type 2 Orifice with Buna-N O-rings** 010137-001
        Type 2 Orifice with Viton O-rings** 010137-003
        Filter Kit, 60 microns 010139-000
        Filter Kit, Coalescing, 0.1 microns 010140-000
        Filter Element Kit (for coalescing filter, package of 10) 010141-000
        Hirschman® Connector Kit (Din 43 650-A)
        (3 prong plug, O-ring sealed)
        010142-000
        Pressure Gauge Kit, 15 PSI 010138-000
        Pressure Gauge Kit, 30 PSI 010138-001
        Pressure Gauge Kit, 60 PSI 010138-002
        Pressure Gauge Kit, 160 PSI 010138-003
        * Type 1 Kits to be used with Ø based output units and 1-17 psig unit.
        ** Type 2 Kits to be used with all other units.
        *** Supplied standard with Nema 4X

        T-1001 Specials Table
        Part Number
        Input
        Output
        Comments
        962-145-000
        4-20 mA
        20-100 kPa
        NEMA 1
        962-146-000
        20-100 kPa
        NEMA 3R
        962-148-000
        0-200 kPa
        NEMA 1

         


        分享到:

         

         